The capacitor start, capacitor run (CSCR) motor adds a run capacitor
to the start capacitor, which provides the motor with better torque characteristics
when the motor is operating at full speed.
The run capacitor is usually oval or square shaped and has a metal housing
rather than plastic. The metal housing allows the run capacitor to radiate
any heat that is built up inside it, since it's connected to remain in
the run winding circuit at all times.
From the diagram in Fig. 1a (below) note that the run capacitor is essentially
connected to the capacitor start, induction run motor. This type of motor
is used almost exclusively for hermetic compressor motors in air-conditioning
systems. One will find air-conditioning systems connected to most modern
electronic panels today to provide the additional cooling that is required
when computers, motor drives, and other amplifiers are placed in an enclosed
cabinet.

Above: Fig. 1: (a) Capacitor start, capacitor run motor connected to
a potential relay. The potential relay is used to energize and de-energize
the start winding. (b) Diagram of a potential relay. (a) Diagram of potential
relay connected to a capacitor start, capacitor run motor; (b) Diagram
of potential relay.
For this motor, the run capacitor is connected in parallel with the
run winding. It will be in the circuit during starting and remain in
the circuit while the motor is running. During the time the motor is
starting, the additional capacitor provides a little more phase shift
than the start capacitor alone, which gives the motor more starting torque.
After the motor is running, the start capacitor is disconnected from
the start winding circuit when the potential relay contacts open, but
the run capacitor remains in the circuit because it’s wired directly
across the R and S terminals. If the load increases slightly because
the compressor is trying to pump more refrigerant, the run capacitor
will provide a small phase shift to give the rotor more torque and regain
the loss of rpm quickly. The larger the load increase is, the more speed
the rotor will lose, which will cause additional current to be drawn.
The increase in current will pass through the run capacitor and cause
it to provide a larger phase shift, which in turn provides the rotor
with more torque. The run capacitor allows the speed of the motor to
remain fairly constant when the load is constantly varying. |